Escudo Universidad de Antioquia

Sistema de Bibliotecas

Universidad de Antioquia

Biblioteca Digital


Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10495/12039
Título : Is the measurement of blood pressure by automatic monitor in the South American pediatric population accurate? SAYCARE Study
Autor : Araújo Moura, Keisyanne
Ferreira De Moraes, Augusto César
Forkert, Elsie C.O.
Berg, Gabriela
Grizzo Cucato, Gabriel
de Moraes Forjaz, Claúdia Lucia
Moliterno, Paula
Gaitán Charry, Diego
Delgado, Carlos A.
González Gil, Esther M.
Moreno, Luis Alberto
Barbosa Carvalho, Heráclito
Torres Leal, Francisco Leonardo
Fecha de publicación : 2018
Editorial : Wiley
Citación : Araújo-Moura K, De-Moraes A, Forkert E, Berg G, Cucato G, et al. Is the measurement of blood pressure by automatic monitor in the South American pediatric population accurate? SAYCARE Study. Obesity. 2019; 26: S41-S46. DOI:10.1002/oby.22119
Abstract : Objective: This study aimed to test the validity of an automatic oscillometric device to measure the blood pressure (BP) in children (n 5 191) and adolescents (n 5 127) aged 3 to 18 years.Methods: Systolic BP (SBP) and diastolic BP (DBP) levels were measured simultaneous by automaticdevice and mercury column with Y-connection. To verify the validity, Bland-Altman plots and limits of agreement of 95% (95% LOA), specificity and sensitivity of the device, and the grade of British Hypertension Society (BHS) criteria were used. Results: The monitor measurements demonstrated lower measurement bias (mean difference [95% LOA]): 1.4 (29.9 to 12.8) mmHg in children and 4.3 (27.8 to 16.5) mmHg in adolescents for SBP. For DBP, it was 2.2 (27.4 to 11.7) mmHg in children and 1.4 (28.4 to 11.1) mmHg in adolescents. The sensitivity in children was 21.4 (95% CI 5 16.3-26.6), and in adolescents, it was 20.0 (95% CI 5 13.2-26.8); the specificity was 95.9 (95% CI 5 93.4-98.4) in children and 100.0 (95% CI 5 100.0-100.0) in adolescents. The monitor-tested ratings are Grade B for SBP in children and SBP and DBP in adolescents and Grade C for DBP in children. Conclusions: The automatic monitor presented high values of specificity and lower values of sensitivity to the diagnosis of HBP; however, it can be considered accurate (lower measurement bias) and valid for epidemiological and clinical practice in accordance with BHS criteria.
Grupo de INV. : Alimentación y Nutrición Humana
URI : http://hdl.handle.net/10495/12039
ISSN : 1930739X
Aparece en las colecciones: CIAN (Centro de Investigación en Alimentación y Nutrición)

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
AraujoKeisyanne _2018_MeasurementBloodPressureAutomatic.pdfArtículo de revista 364,79 kBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.

 


Unidad de Gestión Tecnológica /Sistema de Bibliotecas / Universidad de Antioquia / Cl. 67 Nº 53 - 108 - Bloque 8 Conmutador: 219 51 51- 219 51 40 comunicacionessistemadebibliotecas@udea.edu.co Medellín - Colombia