Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10495/8445
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorJaramillo Gómez, Carlos David-
dc.contributor.authorEchavarría Velásquez, Alejandro Iván-
dc.contributor.authorO'Byrne, Johan-
dc.contributor.authorCongote, Diego-
dc.contributor.authorRestrepo Betancur, Luis Fernando-
dc.date.accessioned2017-10-04T14:23:58Z-
dc.date.available2017-10-04T14:23:58Z-
dc.date.issued2010-
dc.identifier.citationJaramillo Gómez CD, Echavarría Velásquez AI, O'byrne J, Restrepo Betancur LF. Osteoconductive and osseointegration properties of a commercial hydroxyapatite compared to a synthetic product. Rev. Colomb. Cienc. Pecu. 2010; 23(4): 471-483es_ES
dc.identifier.issn01200690-
dc.identifier.issn22562958 E-
dc.identifier.urihttp://hdl.handle.net/10495/8445-
dc.descriptionEn el presente artículo se evalúan las propiedades de osteoconducción y osteointegración de una hidroxiapatita reabsorbible (OseoU), procesada a dos temperaturas diferentes de calcinación (Tipo A y Tipo B), con el propósito de compararlas con un preparado comercial de hidroxiapatita (Osteogen®), utilizado para múltiples procedimientos quirúrgicos en los cuales se involucra la pérdida de tejido óseo. La síntesis se realizó en los laboratorios de la Universidad de Antioquia por el método de precipitación acuosa de la mezcla de nitrato de calcio y de fosfato de amonio. Los productos obtenidos y la hidroxiapatita comercial fueron caracterizados por microscopia electrónica de barrido (SEM), difracción de rayos X (DRX), espectroscopia de infrarrojo transformada de Fourier (FTIR) y espectrometría por energía dispersiva (EDS). Las características de osteoconducción y osteointegración fueron medidas de acuerdo a la capacidad de los productos para inducir la diferenciación de células locales a células formadoras de hueso. Dichas características, se evaluaron en implantes de hidroxiapatita realizados en 70 conejos de la raza Nueva Zelanda distribuidos en siete grupos de 10 animales cada uno, evaluados a los 7, 14, 21, 28, 42, 60 y 90 días de efectuado el procedimiento quirúrgico. Los resultados obtenidos demostraron que el OseoU y el Osteogen®, presentaron características similares en cuanto a la estructura cristalina, la composición química y la adsorción, con apreciables diferencias morfológicas con respecto a la forma de las partículas. Al realizar el análisis de varianza no se encontraron diferencias estadísticas significativas para las variables histopatológicas evaluadas en las dos hidroxiapatitas (p>0.05), indicando que las hidroxiapatitas sintetizadas en la Universidad de Antioquia (OseoU) tuvieron el mismo resultado que la hidroxiapatita comercial (Osteogen®) en la osteoconducción y la osteointegración del tejido óseo.es_ES
dc.description.abstractThe effects of two types of hydroxylapatite on bone synthesis and properties were evaluated. An osteoconductive resorbable hydroxyapatite (OseoU), synthesized at two different temperatures of calcination (Type A and Type B) was compared with a commercial mixture of hydroxyapatite (Osteogen®), commonly used in several surgical procedures involving bone loss. The synthesis was performed in the laboratories of the University of Antioquia by precipitating a mixture of calcium nitrate and ammonium phosphate. The products obtained and the commercial hydroxyapatite were characterized by scanning electron microscopy (SEM), X- ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), and energy dispersive spectroscopy (EDS). Osteoconductive and osseointegration characteristics were measured according to the products ability to induce local cell differentiation into bone forming cells. These characteristics were evaluated in hydroxyapatite implants performed in 70 New Zealand breed rabbits distributed into seven groups of 10 animals each, tested at 7, 14, 21, 28, 42, 60 and 90 days after the surgical procedure. seven groups of 10 animals each, tested at 7, 14, 21, 28, 42, 60 and 90 days after the surgical procedure. The results showed that Osteogen® and OseoU have similar characteristics in terms of crystal structure, chemical composition and adsorption properties, but morphological differences regarding particle shape. The analysis of variance found no statistically significant differences for the histopathological variables evaluated in both hydroxyapatite groups (p>0.05), indicating that the hydroxyapatites synthesized at the University of Antioquia (OseoU) had the same results as the commercial hydroxyapatite.es_ES
dc.format.extent471-483es_ES
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoenes_ES
dc.publisherUniversidad de Antioquia, Facultad de Ciencias Agrariases_ES
dc.type.hasversioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.sourceinstname: Universidad de Antioquiaes_ES
dc.sourcereponame: Repositorio Institucional Universidad de Antioquiaes_ES
dc.sourceRevista Colombiana de Ciencias Pecuariases_ES
dc.subjectBone regenerationes_ES
dc.subjectHydroxyapatitees_ES
dc.subjectOosteoconductiones_ES
dc.subjectOsseointegrationes_ES
dc.subjectSynthetic bone substituteses_ES
dc.subjectOsteoconducciónes_ES
dc.subjectOseointegraciónes_ES
dc.subjectHidroxiapatitases_ES
dc.subjectRegeneración óseaes_ES
dc.subjectSustitutos del huesoes_ES
dc.titleOsteoconductive and osseointegration properties of a commercial hydroxyapatite compared to a synthetic productes_ES
dc.title.alternativeComparación de las propiedades de osteoconducción y osteointegración de una hidroxiapatita reabsorbible comercial con una hidroxiapatita reabsorbible sintetizadaes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.volumen23es_ES
dc.relation.numero4es_ES
dc.source.tituloRevistaAbreviadaRev. Colomb. Cienc. Pecu.es_ES
Aparece en las colecciones: CIAG (Centro de investigaciones Agrarias)

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
RestrepoLuis_2010_OsteoconductiveOsseoProperties.pdfArtículo de Revista724,17 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

 


Gestión de T.I. /Sistema de Bibliotecas / Universidad de Antioquia / Cl. 67 Nº 53 - 108 - Bloque 8 Conmutador: 219 51 51- 219 51 40 comunicacionessistemadebibliotecas@udea.edu.co Medellín - Colombia