Escudo Universidad de Antioquia

Sistema de Bibliotecas

Universidad de Antioquia

Biblioteca Digital


Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10495/8578
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorGiraldo Buitrago, Lina Claudiaes_ES
dc.contributor.authorPalacio Tobón, Carlos Albertoes_ES
dc.contributor.authorMolina Santamaría, Rubén Daríoes_ES
dc.contributor.authorAgudelo García, Rubén Albertoes_ES
dc.date.accessioned2017-10-18T19:55:56Z-
dc.date.available2017-10-18T19:55:56Z-
dc.date.issued2015-
dc.identifier.citationL. C. Giraldo-Buitrago, C. A. Tobón-Palacio, R. D. Molina-Santamaría and R. A. Agudelo-García, "Water quality modeling of the Medellin river in the Aburrá Valley," DYNA, vol. 82, no. 192, pp. 195-202, 2015.es_ES
dc.identifier.issn00127353-
dc.identifier.issn23462183 E-
dc.identifier.urihttp://hdl.handle.net/10495/8578-
dc.descriptionLa modelación de la calidad del agua busca representar un cuerpo de agua con el fin de evaluar su estado y proyectar los efectos de diferentes medidas que se tomen para su protección. En este artículo se presentan los resultados obtenidos a partir de la implementación del modelo Qual2Kw en los primeros 50 kilómetros del río Aburrá-Medellín, en sus condiciones más críticas de calidad de agua, que corresponden a caudales bajos. Una vez obtenido el modelo calibrado, se evaluaron tres escenarios de recuperación (corto-2años, mediano- 5años y largo plazo-10años). En el primer escenario sólo se consideraron mejoras en el saneamiento de algunas quebradas de acuerdo con el Plan de Saneamiento y Manejo de Vertimientos (PSMV), mientras que los escenarios a mediano y largo plazo consideraron la operación de la Planta de Tratamiento de Aguas Residuales (PTAR) de Bello y un aumento en la colección de aguas residuales. Los resultados obtenidos evidencian el impacto positivo del funcionamiento de la PTAR de Bello en los balances de DBO5, oxígeno disuelto y Nitrógeno. Palabras clave: modelación de calidad del agua, río Aburrá-Medellín.es_ES
dc.description.abstractWater quality modeling intends to represent a water body in order to assess their status and project the effects of different measures taken for their protection. This paper presents the results obtained from the Qual2kw model implementation in the first 50 kilometers of the Aburrá-Medellín River, in their most critical conditions of water quality, which correspond to low flow rates. After the model calibration, three recovery scenarios (short-term, medium-term and long-term) were evaluated. In the first scenario the sanitation only improved in some streams, in accordance with the Plan of Sanitation and Management of Discharges that was considered. Medium and long-term scenarios, with the operation of the new Water Waste Treatment Plant (WWTP) of the Bello municipality and an increase in the sewage collection, were considered. The obtained results show the positive impact of the operation of the WWTP of Bello in the balance of BOD5, dissolved oxygen and nitrogen. Keywords: water quality modeling; Aburrá-Medellín River.en_EN
dc.format.extent195-202es_ES
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoenes_ES
dc.publisherFacultad de Minas - Universidad Nacional de Colombiaes_ES
dc.type.hasversioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.sourceinstname: Universidad de Antioquiaes_ES
dc.sourcereponame: Repositorio Institucional Universidad de Antioquiaes_ES
dc.sourceRevista Dynaes_ES
dc.subjectCalidad del agua - Antioquiaes_ES
dc.subjectRío Medellínes_ES
dc.subjectRío Medellín - Contaminaciónes_ES
dc.subjectRío Medellín - Evaluación ambientales_ES
dc.subjectValle de Aburrá (Antioquia, Colombia)es_ES
dc.subjectModelaciónes_ES
dc.subjectWater Qualityen
dc.subjectSanitary Engineeringen
dc.subjectEnvironmental engineeringen
dc.titleWater quality modeling of the Medellin river in the Aburrá Valleyes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.publisher.groupGrupo de Ingeniería y Gestión Ambiental (GIGA)es_ES
dc.identifier.doi10.15446/dyna.v82n192.42441-
dc.relation.volumen8es_ES
dc.relation.numero192es_ES
Aparece en las colecciones: CIA (Centro de Investigaciones Ambientales y de Ingeniería)

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
GiraldoLina_2015_WaterQualityModelingMedellin.pdfArtículo de Revista1,04 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

 


Unidad de Gestión Tecnológica /Sistema de Bibliotecas / Universidad de Antioquia / Cl. 67 Nº 53 - 108 - Bloque 8 Conmutador: 219 51 51- 219 51 40 comunicacionessistemadebibliotecas@udea.edu.co Medellín - Colombia